Operating instructions
D3G283-AB32-11
Translation of the original operating instructions
4.4 Connection screen
No. Conn. Designation Colour Function / assignment
1 1 PE green/
yellow
Ground wire
1 3 N blue Supply voltage, neutral conductor, 50/60 Hz
1 4 L black Supply voltage, phase, 50/60 Hz
1 5 COM white 1 Floating status message contact, normally closed connection (2 A, max. 250 VAC,
min. 10 mA, AC1)
1 6 NC white 2 Floating status message contact, normally closed connection
2 8 0-10 V yellow Control input, set value 0-10 VDC, impedance 100 kΩ, SELV
2 10 P orange not assigned
2 11 10 VDC red Voltage output 10 VDC (+/-3 %), max. 10 mA, supply voltage for external devices (e.g.
potentiometer), SELV
2 12 GND blue Reference mass for control interface, SELV