A3G910-AV02-35
Translation of the original operating instructions
3.2 Nominal data
Motor M3G150-NA
Phase 3~
Nominal voltage / VAC 400
Nominal voltage
range / VAC
380 .. 480
Frequency / Hz 50/60
Type of data definition ml
Speed / min
-1
1000
Power input / W 2880
Current draw / A 4.4
Max. back pressure / Pa 190
Min. ambient temperature
/ °C
-25
Max. ambient
temperature
/ °C
65
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category A
Efficiency category Static
Variable speed drive Yes
Specific ratio
*
1.00
*
Specific ratio = 1 + pfs / 100 000 Pa
Actual Request
2013
Request
2015
Overall efficiency ηes / % 44.5 32.6 36.6
Efficiency grade N 47.9 36 40
Power input Ped / kW 2.93
Air flow qv / m³/h 22085
Pressure increase total psf / Pa 202
Speed n / min
-1
1005
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass 32 kg
Size 910 mm
Surface of rotor Coated in black
Material of electronics
housing
Die-cast aluminium, coated in black
Material of blades Aluminium sheet insert (coated in black),
sprayed with PP plastic
Number of blades 5
Blade angle
Direction of air flow "A"
Direction of rotation Counter-clockwise, seen on rotor
Type of protection IP 54
Insulation class "F"
Humidity class F5
Mounting position Shaft horizontal or rotor on top; rotor on
bottom on request
Condensate discharge
holes
On the stator side
Operation mode S1
Motor bearing Ball bearing
Technical features - Output 10 VDC, max. 10 mA
- Output 20 VDC, max. 50 mA
- Output for slave 0-10 V
- Operation and alarm display
- Input for sensor 0-10 V or 4-20 mA
- External 24 V input (programming)
- External release input
- Alarm relay
- Integrated PID controller
- Motor current limit
- PFC, passive
- RS485 MODBUS RTU
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from the mains
- Over-temperature protected
electronics / motor
- Line undervoltage / phase failure
detection
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads Via terminal box
Motor protection Reverse polarity and locked-rotor
protection
Protection class I (if protective earth is connected by
customer)
Product conforming
to standard
EN 61800-5-1; CE
Approval C22.2 Nr.77 + CAN/CSA-E60730-1;
EAC; UL 1004-7 + 60730
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 51473-5-9970 · ENG · Revision 82539 · Release 2014-05-08 · Page 5 / 12