Ebm-papst S3G350-AN01-32 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Ebm-papst S3G350-AN01-32. ebm-papst S3G350-AN01-32 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 10
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Operating instructions
S3G350-AN01-32
Translation of the original operating instructions
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 (0) 7938 81-0
Fax +49 (0) 7938 81-110
www.ebmpapst.com
CONTENTS
1. SAFETY REGULATIONS AND NOTES
11. SAFETY REGULATIONS AND NOTES
Please read these operating instructions carefully before starting to work
with the device. Observe the following warnings to prevent malfunctions
or physical damage to both property and people.
These operating instructions are to be regarded as part of this device.
If the device is sold or transferred, the operating instructions must
accompany it.
These operating instructions may be duplicated and forwarded for
information about potential dangers and their prevention.
1.1 Levels of hazard warnings
11.1 Levels of hazard warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury. Compliance with
the measures is mandatory.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury. Exercise extreme
caution while working.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury or damage of property.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
1.2 Staff qualification
11.2 Staff qualification
The device may only be transported, unpacked, installed, operated,
maintained and otherwise used by trained and authorised technical staff.
Only authorised specialists are permitted to install the device, to carry
out a test run and to perform work on the electrical installation.
1.3 Basic safety rules
11.3 Basic safety rules
Any safety hazards stemming from the device must be re-evaluated
once it is installed in the end device.
Observe the following when working on the unit:
; Do not make any modifications, additions or conversions to the
device without the approval of ebm-papst.
1.4 Electrical voltage
11.4 Electrical voltage
; Check the electrical equipment of the device at regular intervals, refer
to chapter 6.2 Safety test.
; Replace loose connections and defective cables immediately.
DANGER
Electrical load on the device
Risk of electric shock
Stand on a rubber mat if you are working on an electrically
charged device.
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
Wait five minutes after disconnecting the voltage at all poles
before opening the device.
21.5 Safety and protective functions
21.6 Electromagnetic radiation
21.7 Mechanical movement
21.8 Emission
21.9 Hot surface
21.10 Storage
21.11 Disposal
32. PROPER USE
43. TECHNICAL DATA
43.1 Product drawing
53.2 Nominal data
53.3 Data according to ErP directive
53.4 Technical features
53.5 Mounting data
53.6 Transport and storage conditions
64. CONNECTION AND START-UP
64.1 Connecting the mechanical system
64.2 Connecting the electrical system
64.3 Connection of the cables
74.4 Connection screen
84.5 Checking the connections
84.6 Switch on device
84.7 Switching off the device
85. INTEGRATED PROTECTIVE FUNCTIONS
96. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
96.1 Cleaning
96.2 Safety test
Item no. 51544-5-9970 · Revision 79127 · Release 2013-03-26 · Page 1 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
Vue de la page 0
1 2 3 4 5 6 7 8 9 10

Résumé du contenu

Page 1 - Operating instructions

Operating instructionsS3G350-AN01-32Translation of the original operating instructionsebm-papst Mulfingen GmbH & Co. KGBachmühle 2D-74673 Mulfinge

Page 2

Operating instructionsS3G350-AN01-32Translation of the original operating instructionsMounting ofprotectiveearth connectionVisual inspection At least

Page 3

Operating instructionsS3G350-AN01-32Translation of the original operating instructionsCAUTIONIn the event of failure, there is electric voltage at the

Page 4

Operating instructionsS3G350-AN01-32Translation of the original operating instructions2. PROPER USEThe device is exclusively designed as a built-in de

Page 5

Operating instructionsS3G350-AN01-32Translation of the original operating instructions3. TECHNICAL DATA3.1 Product drawingAll measures have the unit m

Page 6

Operating instructionsS3G350-AN01-32Translation of the original operating instructions3.2 Nominal dataMotor M3G074-CFPhase 1~Nominal voltage / VAC 230

Page 7

Operating instructionsS3G350-AN01-32Translation of the original operating instructions4. CONNECTION AND START-UP4.1 Connecting the mechanical systemCA

Page 8

Operating instructionsS3G350-AN01-32Translation of the original operating instructions4.4 Connection screenNo. Conn. Designation Colour Function / ass

Page 9

Operating instructionsS3G350-AN01-32Translation of the original operating instructions4.5 Checking the connections; Make sure that the power is off (a

Page 10

Operating instructionsS3G350-AN01-32Translation of the original operating instructions6. MAINTENANCE, MALFUNCTIONS, POSSIBLECAUSES AND REMEDIESDo not

Commentaires sur ces manuels

Pas de commentaire